Roof Snow Load Connecticut
Only relatively recently have drifting and sliding snow loads been addressed in building codes.
Roof snow load connecticut. The sloped roof snow load p s shall be obtained by multiplying the flat roof snow load p f by the roof slope factor c s. Other considerations for sloped roofs can be found throughout chapter 7 of asce 7 10. Why snow load information. A great deal of confusion currently exists among engineers architects recreation specialists and maintenance personnel concerning the proper snow loading to use for the design and maintenance of trail bridges building roofs and other structures in mountainous high snow load areas.
Wood and steel structures may show noticeable signs of excessive deflection before failure. Once the ground snow load at the building site is determined it must then be converted to roof snow loads according to asce 7 with appropriate treatment of exposure to wind thermal properties of the roof roof slope unbalanced snow loads drifting and risk exposure. The publication is 20 and may be purchased from msu civil engineering at 406 994 2111. Snow loads acting on a sloping surface shall be assumed to act on the horizontal projection of that surface.
The rafter span tables within the body of the irc are limited to ground snow loads of 30 psf and 50 psf. Overstressed roof deck or framing typically displays some warning signs. Unbalanced roof snow loads were not introduced in ubc until 1988. If you need to gather ground snow load data programmatically please consider our api service.
If you live in the us our snow load calculator compares the total weight on your roof with the permissible load calculated according to the standards issued by the american society of civil engineers regarding the minimum design loads for buildings and other structures asce7 16. In our case let s assume that our structure has a flat roof roof slope 5. Please review our state snow loads page to investigate state specific snow load requirements. Incorporated into boca in 1975.
For additional questions or concerns about specific ground snow loads please call us at 1 425 741 5555. P s c s p f. Table r301 2 1 climatic and geographic design criteria ground snow load. A building constructed 40 years ago may not have been designed for snow loads as they are understood today.
The following warning signs are common in wood metal and steel constructed buildings. In appendix r that has been included in the connecticut amendments to the 2012 international residential code a number of municipalities have ground snow loads of 35 psf and 40 psf. The minimum design roof snow load after allowed reductions shall be 30 psf. The snow load that is applied to our structure is not the ground snow load but in most cases the flat roof snow load.