Proper Clearance Between Chimney And Roof
This will generally cause you fewer problems as a homeowner.
Proper clearance between chimney and roof. Masonry chimneys must terminate. Determine proper chimney height using the 10 2 rule. When passing through the roof you need to use a flashing that matches the roof pitch. The edge of the roof has thin metal flashing that helps water drip off the roof without damaging the home or causing a leak.
The sketch at left shows the proper minimum chimney height and roof clearances for a masonry chimney. And a rain cap protects the inside of the flue. What is the 2 foot 10 foot 3 foot rule. If you choose the latter method ensure the chimney pipe maintains proper clearances.
Type b vents ceiling floor wall clearances b vent clearances to combustibles clearance distances for a b vent to combustible materials in floors walls ceilings attics roofs. This rule refers to the proper height of the chimney pipe above the roof. One of the most important aspects of the planning process is installing the proper amount of chimney pipe above the roof. The chimney must extend at least 3 above the highest point where it passes through a roof.
At least 3 feet above the highest point of contact with the roof structure the vertical green arrow in our sketch at left and. Chimneys located entirely outside the exterior walls of the building including chimneys that pass through the soffit or cornice shall have a minimum air space clearance of 1 inch 25 4 mm. The plan on the left shows a code compliant chimney through floor or roof framing with a 2 air space between the masonry chimney walls and the combustible framing. This guideline is the same for exposed naked chimney s as it is for enclosed chimney s in a chase.
We discuss fire safety fire clearances and other gas appliance venting details for b vent chimneys. If you ve been researching class a chimney pipes you ve probably heard of the 3 2 10 foot rule numerous times. The proper name for the connection between a manufactured chimney flue and the. A clearance gap of inches is required between a manufactured chimney and combustibles.
While some skylight manufacturers include flashing in their products sometimes roofing professionals have to create it or purchase it separately. Masonry chimney clearances ibc code change proposals s232 12 and s237 12 by jim buckley chair. Open valleys have metal flashing to protect this critical area of the roof. This article series describes b vent metal chimneys used for gas fired appliances.
Masonry chimney roof clearance requirements. Positing a chimney on the home relative to the rest of the home may cause it to draw better. Chimneys should extend upwards. This guideline has 3 main.
The difference between a chimney cap and. A rain cap or deflector is required on all manufactured chimneys.